Research Report

Handheld Electronic Nose (HEN) for Detection of Optimum Fermentation Time during Tea Manufacture and Assessment of Tea Quality  

Nagulan Manigandan , V.A. Shanmugaselvam , P. Surendar
Tea Technology Division, UPASI Tea Research Foundation, Regional centre,Coonoor, The Nilgiris District, TamilNadu -643 101
Author    Correspondence author
Journal of Tea Science Research, 2019, Vol. 9, No. 1   doi: 10.5376/jtsr.2019.09.0001
Received: 26 Jun., 2019    Accepted: 23 Aug., 2019    Published: 09 Oct., 2019
© 2019 BioPublisher Publishing Platform
This is an open access article published under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Preferred citation for this article:

Manigandan N., Shanmugaselvam V.A., and Surendar P., 2019, Handheld Electronic Nose (HEN) for detection of optimum fermentation time during tea manufacture and assessment of tea quality, Journal of Tea Science Research, 9(1): 1-6 (doi: 10.5376/jtsr.2019.09.0001)

Abstract

Fermentation is an important process in tea manufacturing cycle and proper fermentation of tea leaves determines the quality of made tea. Both over and under fermentation affects the quality of made tea. To understand the optimum fermentation time and flavour of the processed tea, CDAC Kolkata had developed a hand-held electronic nose system (HEN). The system consists of top, mid and bottom section. Top section contains major portion of electronics, display, pump, sensor array and battery. The detachable mid-section holds the valve and provides an air path between pump and sample holder and between sample holder and sensor array. The bottom section is a threaded glass jar that acts as the sample holder. The HEN can be handy in determining the optimum fermentation end point during manufacturing process and to assess the quality of processed tea based on its aroma. Fixed quantity (half of the sample holder) of sample was taken from fermentation bed at an interval of five minutes and the generated aroma volatiles were discharged to the sensor array. The captured aroma was plotted against time to get the second aroma peak, which determined the optimum end point of fermentation. This was compared with the existing chemical method. The results obtained through HEN were correlated with the existing chemical method. The processed teas consisting CTC and orthodox types of manufacture and different grades were evaluated through HEN and the results were compared with organoleptic evaluation of tea by national and international tea tasters. The results revealed that the Handheld Electronic Nose is a suitable instrument for determining the optimum fermentation time during tea manufacture based on aroma.

Keywords
Tea; Fermentation; Quality; CTC; Orthodox
[Full-Text PDF] [Full-Text HTML]
Journal of Tea Science Research
• Volume 9
View Options
. PDF(289KB)
. HTML
Associated material
. Readers' comments
Other articles by authors
. Nagulan Manigandan
. V.A. Shanmugaselvam
. P. Surendar
Related articles
. Tea
. Fermentation
. Quality
. CTC
. Orthodox
Tools
. Email to a friend
. Post a comment